Thanks to their cadmium-telluride sensor, DECTRIS PILATUS3® R CdTe X-ray detectors are ideal for high-energy laboratory applications that require large-area detection. Direct detection in a hybrid-pixel detector results in sharper signals and better spatial resolution than is possible with scintillator-based detectors. CdTe X-ray detectors also provide more than 95% efficiency for Mo, Ag, and In radiation. Combined with noise-free, single-photon counting, these capabilities permit PILATUS3 R CdTe cameras to achieve new levels of sensitivity and accuracy in the laboratory.
Laboratory X-ray sources, particularly for hard X-rays, are much weaker than sources at a synchrotron, and longer exposure times are required. Thanks to the absence of dark current and readout noise, PILATUS3 R detectors outperform other technologies in this regard. Single-photon counting is also free of other sources of noise and inaccuracy that are intrinsic to charge-integrating CMOS detectors.
- Sensitive: these detectors provide more than 95% efficiency for Mo, Ag, and In radiation.
- Accurate: the detectors offer noise-free detection, even for long exposure times.
- Reliable: detector performance is always stable. Delivery terms are guaranteed, thanks to streamlined industrial production and top-notch support.
Detectors

PILATUS3 R CdTe 1M
This is the largest PILATUS3 detector for high-energy X-ray diffraction and scattering in the laboratory. It is a great solution if you are working in demanding, high-energy applications.

PILATUS3 R CdTe 300K
This detector brings the advantages of hybrid-pixel technology and direct detection in CdTe to high-energy applications, such as charge-density studies or CD-SAXS.

PILATUS3 R CdTe 300K-W
This detector features an active area of 254 x 34 mm2. It is ideal for scanning wide objects in imaging or non-destructive testing.

PILATUS3 R CdTe 100K-M
Its compact detector head fits easily into laboratory setups and offers an active area of 84 x 33.5 mm2.
Detector Specifications*
PILATUS3 R CdTe 1M | PILATUS3 R CdTe 300K | PILATUS3 R CdTe 300K-W | PILATUS3 R CdTe 100K-M | |
---|---|---|---|---|
Active area (W x H) [mm² ] |
168.7 x 179.4 |
83.8 x 106.5 |
253.7 x 33.5 |
83.8 x 33.5 |
Pixel array (W x H) |
981 x 1,043 |
487 x 619 |
1,475 x 195 |
487 x 195 |
Pixel size (W x H) [µm² ] |
172 x 172 |
172 x 172 |
172 x 172 |
172 x 172 |
Inter-module gap (Hor./Vert.) [pixels ] |
7 / 17 |
- / 17 |
7 / - |
- / - |
Intra-module gap (Hor.) [pixels ] |
1 |
1 |
1 |
1 |
Count rate (max.) [ph/s/pixel ] |
107 |
107 |
107 |
107 |
Energy range [keV ] |
15 - 80 |
15 - 80 |
15 - 80 |
15 - 80 |
Frame rate (max.) [Hz ] |
5 |
20 |
20 |
20 |
Readout time [ms ] |
7 |
7 |
7 |
7 |
Sensor material |
Cadmium telluride (CdTe) |
Cadmium telluride (CdTe) |
Cadmium telluride (CdTe) |
Cadmium telluride (CdTe) |
Sensor thickness [µm ] |
1,000 |
1,000 |
1,000 |
1,000 |
Point-spread function (FWHM) [pixels ] |
1 |
1 |
1 |
1 |
Vacuum compatibility |
Contact us |
Optional |
Optional |
Optional |
Dimensions (W x H x D) [mm³ ] |
265 x 286 x 455 |
158 x 193 x 262 |
280 x 62 x 296 |
114 x 69 x 118 (Detector head) |
Weight [kg ] |
25 |
7.5 |
7 |
0.9 (Detector head) |
Cooling method |
Water |
Water |
Water |
Water (Detector head) |
|
*All specifications are subject to change without notice.
Key Contact
Request a quote